1. The altitude should not exceed 1000m. The ambient air temperature is -25ºC~+40ºC. The relative humidity of the ambient air does not exceed 85% (+25°C), and there is no corrosive gas. It is not suitable to lift high temperature or toxic, flammable and explosive cargo.
2. The rated voltage of the power supply is 380V and the rated frequency is 50Hz.Type | HC164 | HC164 II | HC164 | HC164 II | HC164 | ||||||||||||||||||||||||||||||||||||||
Lifting Weight | 16 | 20 | 32 | ||||||||||||||||||||||||||||||||||||||||
Lifting Height (m) |
12 | 16 | 24 | 32 | 36 | 42 | 48 | 9 | 12 | 15 | 18 | 21 | 24 | 27 | 30 | 33 | 36 | 9 | 12 | 18 | 24 | 9 | 12 | 15 | 18 | 21 | 24 | 27 | 30 | 9 | 12 | 16 | 20 | 24 | |||||||||
Lifting Speed (m/min) |
6(0.6/6) | 4.2(0.42/4.2) | 3.3(0.33/3.3) | 4.2(0.42/4.2) | 3(0.3/3) | ||||||||||||||||||||||||||||||||||||||
Travelling Speed (m/min) |
18 | 14 | 16 | ||||||||||||||||||||||||||||||||||||||||
Wire Rope | Dia (mm) |
26 | 17.5 | 21.5 | 26 | ||||||||||||||||||||||||||||||||||||||
Specification | 6×37 | ||||||||||||||||||||||||||||||||||||||||||
Travelling Track | 50a~63c | 56a~63c | >63c | ||||||||||||||||||||||||||||||||||||||||
Min curvature Radius(m) |
3 | 3.5 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 |
Lifting Motor | Type | ZD×62-6(ZDS1) | Zd151-4(ZDS1) | Zd152-4(ZDS1) | ZD×62-6(ZDS1) |
Power (kw) |
18.5(2.2/18.5) | 13(1.5/13) | 18.5(2.2/18.5) | 18.5(2.2/18.5) | |
Rotation Speed (r/min) |
960 | 1400 | 960 | ||
Current(A) | 43 | 30(5.2/30) | 42 | 43 | |
Travelling Motor | Type | ZDY121-4 | ZDY(D)121-4 | ZDY121-4 | |
Power(kw) | 0.8×4 | 0.8×2 | 0.8×4 | ||
Rotation Speed (r/min) |
1380 | ||||
Current(A) | 2.4 | 4.3 | |||
No.of connecting (frequency) |
120 | ||||
Working System | Intermediate FC=25% | ||||
Power Source | 3 Phase AC 380V 50Hz |